Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38519293

RESUMO

Optimal surgical and medical management of obstructive sleep apnea (OSA) requires clinically reliable identification of patterns and sites of upper airway obstruction. A wide variety of modalities has been used to evaluate upper airway obstruction. Drug-induced sleep endoscopy (DISE) and cine MRI are increasingly used to identify upper airway obstruction sites, to characterize airway obstruction patterns, to determine optimum medical and surgical treatment, and to plan individualized surgical management. Here, the authors provide an overview of the applications of DISE and cine MRI in assessing upper airway obstruction in children and adults with OSA.

2.
Phys Med Biol ; 69(9)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38479004

RESUMO

Objective. 3D cine-magnetic resonance imaging (cine-MRI) can capture images of the human body volume with high spatial and temporal resolutions to study anatomical dynamics. However, the reconstruction of 3D cine-MRI is challenged by highly under-sampled k-space data in each dynamic (cine) frame, due to the slow speed of MR signal acquisition. We proposed a machine learning-based framework, spatial and temporal implicit neural representation learning (STINR-MR), for accurate 3D cine-MRI reconstruction from highly under-sampled data.Approach. STINR-MR used a joint reconstruction and deformable registration approach to achieve a high acceleration factor for cine volumetric imaging. It addressed the ill-posed spatiotemporal reconstruction problem by solving a reference-frame 3D MR image and a corresponding motion model that deforms the reference frame to each cine frame. The reference-frame 3D MR image was reconstructed as a spatial implicit neural representation (INR) network, which learns the mapping from input 3D spatial coordinates to corresponding MR values. The dynamic motion model was constructed via a temporal INR, as well as basis deformation vector fields (DVFs) extracted from prior/onboard 4D-MRIs using principal component analysis. The learned temporal INR encodes input time points and outputs corresponding weighting factors to combine the basis DVFs into time-resolved motion fields that represent cine-frame-specific dynamics. STINR-MR was evaluated using MR data simulated from the 4D extended cardiac-torso (XCAT) digital phantom, as well as two MR datasets acquired clinically from human subjects. Its reconstruction accuracy was also compared with that of the model-based non-rigid motion estimation method (MR-MOTUS) and a deep learning-based method (TEMPEST).Main results. STINR-MR can reconstruct 3D cine-MR images with high temporal (<100 ms) and spatial (3 mm) resolutions. Compared with MR-MOTUS and TEMPEST, STINR-MR consistently reconstructed images with better image quality and fewer artifacts and achieved superior tumor localization accuracy via the solved dynamic DVFs. For the XCAT study, STINR reconstructed the tumors to a mean ± SD center-of-mass error of 0.9 ± 0.4 mm, compared to 3.4 ± 1.0 mm of the MR-MOTUS method. The high-frame-rate reconstruction capability of STINR-MR allows different irregular motion patterns to be accurately captured.Significance. STINR-MR provides a lightweight and efficient framework for accurate 3D cine-MRI reconstruction. It is a 'one-shot' method that does not require external data for pre-training, allowing it to avoid generalizability issues typically encountered in deep learning-based methods.


Assuntos
Neoplasias , Respiração , Humanos , Imagem Cinética por Ressonância Magnética , Imageamento Tridimensional/métodos , Movimento (Física) , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
3.
J Magn Reson Imaging ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38436994

RESUMO

BACKGROUND: Balanced steady-state free precession (bSSFP) imaging is commonly used in cardiac cine MRI but prone to image artifacts. Ferumoxytol-enhanced (FE) gradient echo (GRE) has been proposed as an alternative. Utilizing the abundance of bSSFP images to develop a computationally efficient network that is applicable to FE GRE cine would benefit future network development. PURPOSE: To develop a variable-splitting spatiotemporal network (VSNet) for image reconstruction, trained on bSSFP cine images and applicable to FE GRE cine images. STUDY TYPE: Retrospective and prospective. SUBJECTS: 41 patients (26 female, 53 ± 19 y/o) for network training, 31 patients (19 female, 49 ± 17 y/o) and 5 healthy subjects (5 female, 30 ± 7 y/o) for testing. FIELD STRENGTH/SEQUENCE: 1.5T and 3T, bSSFP and GRE. ASSESSMENT: VSNet was compared to VSNet with total variation loss, compressed sensing and low rank methods for 14× accelerated data. The GRAPPA×2/×3 images served as the reference. Peak signal-to-noise-ratio (PSNR), structural similarity index (SSIM), left ventricular (LV) and right ventricular (RV) end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were measured. Qualitative image ranking and scoring were independently performed by three readers. Latent scores were calculated based on scores of each method relative to the reference. STATISTICS: Linear mixed-effects regression, Tukey method, Fleiss' Kappa, Bland-Altman analysis, and Bayesian categorical cumulative probit model. A P-value <0.05 was considered statistically significant. RESULTS: VSNet achieved significantly higher PSNR (32.7 ± 0.2), SSIM (0.880 ± 0.004), rank (2.14 ± 0.06), and latent scores (-1.72 ± 0.22) compared to other methods (rank >2.90, latent score < -2.63). Fleiss' Kappa was 0.52 for scoring and 0.61 for ranking. VSNet showed no significantly different LV and RV ESV (P = 0.938) and EF (P = 0.143) measurements, but statistically significant different (2.62 mL) EDV measurements compared to the reference. CONCLUSION: VSNet produced the highest image quality and the most accurate functional measurements for FE GRE cine images among the tested 14× accelerated reconstruction methods. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38485538

RESUMO

Optimal surgical and medical management of obstructive sleep apnea requires clinically reliable identification of patterns and sites of upper airway obstruction. A wide variety of modalities have been used to evaluate upper airway obstruction. Drug-induced sleep endoscopy (DISE) and cine MRI are increasingly used to identify upper airway obstruction sites, to characterize airway obstruction patterns, to determine optimum medical and surgical treatment, and to plan individualized surgical management. Here, we provide an overview of the applications of DISE and cine MRI in assessing upper airway obstruction in children and adults with obstructive sleep apnea.

5.
NMR Biomed ; 37(4): e5091, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38196195

RESUMO

BACKGROUND: Despite the widespread use of cine MRI for evaluation of cardiac function, existing real-time methods do not easily enable quantification of ventricular function. Moreover, segmented cine MRI assumes periodicity of cardiac motion. We aim to develop a self-gated, cine MRI acquisition scheme with data-driven cluster-based binning of cardiac motion. METHODS: A Cartesian golden-step balanced steady-state free precession sequence with sorted k-space ordering was designed. Image data were acquired with breath-holding. Principal component analysis and k-means clustering were used for binning of cardiac phases. Cluster compactness in the time dimension was assessed using temporal variability, and dispersion in the spatial dimension was assessed using the Calinski-Harabasz index. The proposed and the reference electrocardiogram (ECG)-gated cine methods were compared using a four-point image quality score, SNR and CNR values, and Bland-Altman analyses of ventricular function. RESULTS: A total of 10 subjects with sinus rhythm and 8 subjects with arrhythmias underwent cardiac MRI at 3.0 T. The temporal variability was 45.6 ms (cluster) versus 24.6 ms (ECG-based) (p < 0.001), and the Calinski-Harabasz index was 59.1 ± 9.1 (cluster) versus 22.0 ± 7.1 (ECG based) (p < 0.001). In subjects with sinus rhythm, 100% of the end-systolic and end-diastolic images from both the cluster and reference approach received the highest image quality score of 4. Relative to the reference cine images, the cluster-based multiphase (cine) image quality consistently received a one-point lower score (p < 0.05), whereas the SNR and CNR values were not significantly different (p = 0.20). In cases with arrhythmias, 97.9% of the end-systolic and end-diastolic images from the cluster approach received an image quality score of 3 or more. The mean bias values for biventricular ejection fraction and volumes derived from the cluster approach versus reference cine were negligible. CONCLUSION: ECG-free cine cardiac MRI with data-driven clustering for binning of cardiac motion is feasible and enables quantification of cardiac function.


Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Função Ventricular , Análise por Conglomerados , Reprodutibilidade dos Testes
6.
IJU Case Rep ; 7(1): 30-33, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38173447

RESUMO

Introduction: Leiomyosarcoma of the inferior vena cava is associated with poor prognosis. Complete resection is the only curative treatment. We present a patient with this disease in whom cine magnetic resonance imaging was valuable in selecting the surgical strategy and mitigating invasiveness. Case presentation: A 68-year-old woman presented with right-sided abdominal pain. Computed tomography revealed an 86 mm tumor in the right retroperitoneal space that extended into the inferior vena cava and reached superiorly to the right atrium. Percutaneous needle biopsy confirmed leiomyosarcoma. Cine magnetic resonance imaging demonstrated no adhesions between the tumor and the upper segment of inferior vena cava wall, nor with the right atrial wall, indicating resectability. Radical tumor resection was successfully performed without requiring thoracotomy. Conclusion: Cine magnetic resonance imaging appears to be useful in inferior vena cava leiomyosarcoma for evaluating adhesions between the tumor and vessel wall.

7.
IJU Case Rep ; 7(1): 60-63, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38173458

RESUMO

Introduction: Renal cell carcinoma with an inferior vena cava tumor thrombus is a challenging disease that requires a multimodal treatment approach. Pembrolizumab plus lenvatinib has displayed promising efficacy in metastatic renal cell carcinoma. Case presentation: A 61-year-old man was diagnosed with metastatic renal cell carcinoma and a tumor thrombus adhering to the inferior vena cava wall by cine magnetic resonance imaging. After 6 months of pembrolizumab and lenvatinib therapy, tumor shrinkage was detected, excluding the advanced portion of the inferior vena cava thrombus, and nephrectomy and thrombectomy were performed. Adhesion of the tumor thrombus to the inferior vena cava wall was observed during surgery. Resection produced a remarkable pathological complete response with no viable cells in the resected specimens, including the thrombus site. Conclusion: This case highlights the potential of pembrolizumab plus lenvatinib for treating advanced renal cell carcinoma with an inferior vena cava thrombus and the utility of cine magnetic resonance imaging for evaluating thrombus adhesion to the inferior vena cava.

8.
Phys Med Biol ; 69(4)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38232395

RESUMO

Objective. The bowel is an important organ at risk for toxicity during pelvic and abdominal radiotherapy. Identifying regions of high and low bowel motion with MRI during radiotherapy may help to understand the development of bowel toxicity, but the acquisition time of MRI is rather long. The aim of this study is to retrospectively evaluate the precision of bowel motion quantification and to estimate the minimum MRI acquisition time.Approach. We included 22 gynaecologic cancer patients receiving definitive radiotherapy with curative intent. The 10 min pre-treatment 3D cine-MRI scan consisted of 160 dynamics with an acquisition time of 3.7 s per volume. Deformable registration of consecutive images generated 159 deformation vector fields (DVFs). We defined two motion metrics, the 50th percentile vector lengths (VL50) of the complete set of DVFs was used to measure median bowel motion. The 95th percentile vector lengths (VL95) was used to quantify high motion of the bowel. The precision of these metrics was assessed by calculating their variation (interquartile range) in three different time frames, defined as subsets of 40, 80, and 120 consecutive images, corresponding to acquisition times of 2.5, 5.0, and 7.5 min, respectively.Main results. For the full 10 min scan, the minimum motion per frame of 50% of the bowel volume (M50%) ranged from 0.6-3.5 mm for the VL50 motion metric and 2.3-9.0 mm for the VL95 motion metric, across all patients. At 7.5 min scan time, the variation in M50% was less than 0.5 mm in 100% (VL50) and 95% (VL95) of the subsets. A scan time of 5.0 and 2.5 min achieved a variation within 0.5 mm in 95.2%/81% and 85.7%/57.1% of the subsets, respectively.Significance. Our 3D cine-MRI technique quantifies bowel loop motion with 95%-100% confidence with a precision of 0.5 mm variation or less, using a 7.5 min scan time.


Assuntos
Imagem Cinética por Ressonância Magnética , Radioterapia Guiada por Imagem , Humanos , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Radioterapia Guiada por Imagem/métodos
9.
Int J Cardiovasc Imaging ; 40(2): 287-294, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37968429

RESUMO

Although cine MRI-derived radiomics features in the cardiac blood pool have been used to represent cardiac function and motion, the clinical relevance of radiomics features in the great vessels is still unknown. The aim of the present study was to test the hypothesis that cine MRI-derived radiomics features of the pulmonary artery (PA) can represent hemodynamic abnormalities in pulmonary hypertension (PH). With the approval of the institutional review board (IRB), 50 PH patients (21 males, 36-89 years old, diagnosed with right heart catheterization [RHC]) and 23 healthy volunteers (14 males, 26-80 years old) were retrospectively enrolled in this study. All participants underwent cardiac 4D flow and cine MRI (25 retrospective phases) at the right ventricular (RV) outflow tract (RVOT). A total of 93 radiomics features were extracted from RVOT cine images through a fixed size region of interest (ROI) at the proximal part of the PA. The peak values of the 6 first order features were different between the PH patients and controls. 4D flow-derived mean velocity in PA was related to 'Kurtosis' (r = 0.452,), 'Range' (r = 0.426), 'Autocorrelation' (r = 0.407), 'Joint Average' (r = 0.459), 'Sum Average' (r = 0.459), 'High Gray Level Emphasis' (r = 0.41), 'Large Dependence High Gray Level Emphasis' (r = 0.44), 'High Gray Level Run Emphasis' (r = 0.422), 'Gray Level Variance' (r = 0.419), 'High Gray Level Zone Emphasis' (r = 0.451), and 'Small Area High Gray Level Emphasis' (r = 0.415). Mean RV pressure was related to 'Inverse Variance' (r = 0.43) and 'Run Percentage' (r = 0.403). All p values < 0.05. Cine MRI-derived PA radiomics features have the potential to serve as novel imaging biomarkers for representing hemodynamic changes in pulmonary circulation.


Assuntos
Hipertensão Pulmonar , Imagem Cinética por Ressonância Magnética , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Imagem Cinética por Ressonância Magnética/métodos , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Valor Preditivo dos Testes , Hemodinâmica
10.
Med Phys ; 2023 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-38043123

RESUMO

BACKGROUND: Cine magnetic resonance (MR) images have been used for real-time MR guided radiation therapy (MRgRT). However, the onboard MR systems with low-field strength face the problem of limited image quality. PURPOSE: To improve the quality of cine MR images in MRgRT using prior image information provided by the patient planning and positioning MR images. METHODS: This study employed MR images from 18 pancreatic cancer patients who received MR-guided stereotactic body radiation therapy. Planning 3D MR images were acquired during the patient simulation, and positioning 3D MR images and 2D sagittal cine MR images were acquired before and during the beam delivery, respectively. A deep learning-based framework consisting of two cycle generative adversarial networks (CycleGAN), Denoising CycleGAN and Enhancement CycleGAN, was developed to establish the mapping between the 3D and 2D MR images. The Denoising CycleGAN was trained to first denoise the cine images using the time domain cine image series, and the Enhancement CycleGAN was trained to enhance the spatial resolution and contrast by taking advantage of the prior image information from the planning and positioning images. The denoising performance was assessed by signal-to-noise ratio (SNR), structural similarity index measure, peak SNR, blind/reference-less image spatial quality evaluator (BRISQUE), natural image quality evaluator, and perception-based image quality evaluator scores. The quality enhancement performance was assessed by the BRISQUE and physician visual scores. In addition, the target contouring was evaluated on the original and processed images. RESULTS: Significant differences were found for all evaluation metrics after Denoising CycleGAN processing. The BRISQUE and visual scores were also significantly improved after sequential Denoising and Enhancement CycleGAN processing. In target contouring evaluation, Dice similarity coefficient, centroid distance, Hausdorff distance, and average surface distance values were significantly improved on the enhanced images. The whole processing time was within 20 ms for a typical input image size of 512 × 512. CONCLUSION: Taking advantage of the prior high-quality positioning and planning MR images, the deep learning-based framework enhanced the cine MR image quality significantly, leading to improved accuracy in automatic target contouring. With the merits of both high computational efficiency and considerable image quality enhancement, the proposed method may hold important clinical implication for real-time MRgRT.

11.
Expert Rev Gastroenterol Hepatol ; 17(12): 1285-1300, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38096022

RESUMO

INTRODUCTION: Pediatric gastrointestinal motility disorders represent some of the most challenging clinical conditions with largely undefined pathogenetic pathways and therefore limited therapeutic options. Herein, we provide an overview of the recent advances in treatment options for these disorders and their clinical impact. AREAS COVERED: PubMed and Medline databases were searched for relevant articles related to the treatment of achalasia, esophageal atresia, gastroparesis, PIPO and constipation published between 2017 and 2022. In this article, we review and summarize recent advances in management of gastrointestinal motility disorders in children with a particular focus on emerging therapies as well as novel diagnostic modalities that help guide their application or develop new, more targeted treatments. EXPERT OPINION: Gastrointestinal motility disorders represent one of the most challenging conundrums in pediatric age and despite significant advances in investigative tools, the palette of treatment options remain limited. Overall, while pharmacological options have failed to bring a curative solution, recent advances in minimal invasive therapeutic and diagnostic techniques have emerged as potential keys to symptom and quality of life improvement, such as ENDOFLIP, POEM, cine-MRI, fecal microbiota transplantation.


Assuntos
Acalasia Esofágica , Gastroenteropatias , Humanos , Criança , Qualidade de Vida , Gastroenteropatias/diagnóstico , Gastroenteropatias/terapia , Acalasia Esofágica/diagnóstico , Constipação Intestinal , Motilidade Gastrointestinal
12.
Quant Imaging Med Surg ; 13(12): 8009-8019, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106256

RESUMO

Background: Cine-magnetic resonance imaging (MRI) is currently used in real-time tumor tracking during magnetic resonance (MR)-guided radiotherapy. As a type of MRI specified for motion tracking, a few minutes' acquisition results in thousands of 2-dimensional (2D) images. For MR-guided radiotherapy consisting of multiple treatment fractions, the large number of cine-MRI images would be disproportionate to the tight clinical data storage available. To alleviate this issue, the feasibility of compression of cine-MRI via video encoders was investigated in this study. Methods: The cine-MRI images were first sorted into 3 sequences according to their plane orientations. Then, each sequence was reordered according to their acquisition times [time-based (TB)] or content similarities [similarity-based (SB)]. As a result, 3 sequences were obtained for 3 plan orientations. Next, the obtained sequences were processed by a video encoder and the corresponding 3 video files were achieved. We employed 3 popular video encoders: Motion JPEG (M-JPEG), Advanced Video Coding (AVC), and High Efficiency Video Coding (HEVC). The performances of the sequence reordering methods and video encoders were evaluated based on a total of 150 image sets. Results: The mean correlation quantities for SB sequences were higher than those for TB sequences by 3% (sagittal), 2% (coronal), and 1% (transverse), respectively. The average compression ratio (CR) yielded by the SB sequences was higher than that achieved by the TB sequences. Comparing with M-JPEG, the CRs obtained by AVC and HEVC were increased by 58% and 62% (sagittal), 16% and 23% (coronal), and 48% and 56% (transverse), respectively. Among the 3 video encoders, the highest CRs and restoration accuracy were achieved by HEVC. Conclusions: HEVC with inter-frame coding is more effective in reducing the redundant information in consecutive images. It is feasible to implement the video encoder for high-performance cine-MRI compression.

13.
Eur Radiol ; 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38114847

RESUMO

OBJECTIVES: To compare cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) for the quantitative assessment of the left ventricular (LV) trabeculated layer in patients with suspected noncompaction cardiomyopathy (NCCM). MATERIALS AND METHODS: Subjects with LV excessive trabeculation who underwent both CMR and CCT imaging as part of the prospective international multicenter NONCOMPACT clinical study were included. For each subject, short-axis CCT and CMR slices were matched. Four quantitative metrics were estimated: 1D noncompacted-to-compacted ratio (NCC), trabecular-to-myocardial area ratio (TMA), trabecular-to-endocardial cavity area ratio (TCA), and trabecular-to-myocardial volume ratio (TMV). In 20 subjects, end-diastolic and mid-diastolic CCT images were compared for the quantification of the trabeculated layer. Relationships between the metrics were investigated using linear regression models and Bland-Altman analyses. RESULTS: Forty-eight subjects (49.9 ± 12.8 years; 28 female) were included in this study. NCC was moderately correlated (r = 0.62), TMA and TMV were strongly correlated (r = 0.78 and 0.78), and TCA had excellent correlation (r = 0.92) between CMR and CCT, with an underestimation bias from CCT of 0.3 units, and 5.1, 4.8, and 5.4 percent-points for the 4 metrics, respectively. TMA, TCA, and TMV had excellent correlations (r = 0.93, 0.96, 0.94) and low biases (- 3.8, 0.8, - 3.8 percent-points) between the end-diastolic and mid-diastolic CCT images. CONCLUSIONS: TMA, TCA, and TMV metrics of the LV trabeculated layer in patients with suspected NCCM demonstrated high concordance between CCT and CMR images. TMA and TCA were highly reproducible and demonstrated minimal differences between mid-diastolic and end-diastolic CCT images. CLINICAL RELEVANCE STATEMENT: The results indicate similarity of CCT to CMR for quantifying the LV trabeculated layer, and the small differences in quantification between end-diastole and mid-diastole demonstrate the potential for quantifying the LV trabeculated layer from clinically performed coronary CT angiograms. KEY POINTS: • Data on cardiac CT for quantifying the left ventricular trabeculated layer are limited. • Cardiac CT yielded highly reproducible metrics of the left ventricular trabeculated layer that correlated well with metrics defined by cardiac MR. • Cardiac CT appears to be equivalent to cardiac MR for the quantification of the left ventricular trabeculated layer.

14.
Med Phys ; 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38128057

RESUMO

BACKGROUND: In prostate radiotherapy, the intrafractional target motion negatively affects treatment accuracy. Generating internal target volume (ITV) using four-dimensional (4D) images may resolve the issue of intrafractional target motion induced by bladder filling and bowel movement. However, no 4D imaging techniques suitable for the prostate are currently available in clinical practice. PURPOSE: This study aimed to determine the ITV based on cine magnetic resonance imaging (MRI) sequence for intrafractional target motion management in prostate MRI-guided radiotherapy. MATERIALS AND METHODS: A reference ITV was generated in simulation process. Then, the reference ITV was adapted with cine MRI sequence before online planning in each fraction. Finally, the reference ITV was updated with the cine MRI sequence acquired during beam delivery after each fraction. Cine MRI sequences and positioning three-dimensional (3D) MRI from 35 patients were retrospectively collected. Clinical target volume (CTV) coverage was computed according to the two-dimensional contour of CTV and ITV on cine MRI images. Relative target size was calculated as the ratio of the volume of ITV and CTV. Isotropic planning target volume (PTV; 5 mm margin) and anisotropic PTV (3 mm margin in the posterior direction and 5 mm margin in other directions) were generated for comparison. RESULTS: The CTV coverage rate of the proposed ITV had a mean value of 98.61% ± 0.51%, whereas the CTV coverage rates of the isotropic and anisotropic PTVs were 97.43% ± 0.41% and 96.58% ± 0.73%, respectively. The proposed ITV had a relative target size of 1.79 ± 0.17, whereas the anisotropic and isotropic PTVs had relative target sizes of 1.92 ± 0.12 and 2.21 ± 0.19, respectively. For both the CTV coverage rate and target relative size, significant differences were observed between the proposed ITV and the other two PTVs (p < 0.05). CONCLUSION: The ITV achieved higher CTV coverage with smaller size than conventional isotropic and anisotropic PTVs, indicating that it can effectively deal with the intrafractional movement of the prostate.

15.
Biomedicines ; 11(11)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-38001933

RESUMO

BACKGROUND: During a cardiac cycle, intracranial pressure is related to arterial entry into the cranium and its interaction with intracranial compliance. The arterial inflow is compensated by intracranial compliance and, initially, the flushing of cerebrospinal fluid (CSF) into the cervical subarachnoid spaces. Our objective is to analyze the interactions between intracranial arteriovenous exchange and cerebrospinal fluid oscillations. METHOD: A total of 23 patients (73 ± 8 years) with suspected chronic hydrocephalus (CH) underwent an infusion test and phase-contrast MRI. Rout is an important factor in the diagnosis of CH. Patients were divided into 2 populations: probableCH (Rout: resistance to CSF outflow) (Rout > 12 mmHg/mL/min, 13 patients) and unlikelyCH (Rout < 12 mmHg/mL/min, 10 patients). We measured the intracranial vascular volume (arteriovenous stroke volume: SVvasc) and CSF (CSF stroke volume at upper cervical level: SVCSF) volume variations during the cardiac cycle. RESULTS: In the whole population, we observed a significant correlation between SVvasc and SVCSF (R2 = 0.43; p = 0.0007). In the population unlikelyCH, this correlation was significant (R2 = 0.76; p = 0.001). In the population probableCH, this correlation was not significant (R2 = 0.17, p = 0.16). CONCLUSIONS: These results show that the link between the compliance of the oscillating CSF and the abrupt arterial inflow seems to be altered in CH. CSF oscillations between intracranial and cervical fluid spaces limit the impact of the abrupt arterial inflow.

16.
Phys Med Biol ; 68(24)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-37918023

RESUMO

Objective. It was a great challenge to train an excellent and generalized model on an ultra-small data set composed of multi-orientation cardiac cine magnetic resonance imaging (MRI) images. We try to develop a 3D deep learning method based on an ultra-small training data set from muti-orientation cine MRI images and assess its performance of automated biventricular structure segmentation and function assessment in multivendor.Approach. We completed the training and testing of our deep learning networks using only heart datasets of 150 cases (90 cases for training and 60 cases for testing). This datasets were obtained from three different MRI vendors and each subject included two phases of the cardiac cycle and three cine sequences. A 3D deep learning algorithm combining Transformers and U-Net was trained. The performance of the segmentation was evaluated using the Dice metric and Hausdorff distance (HD). Based on this, the manual and automatic results of cardiac function parameters were compared with Pearson correlation, intraclass correlation coefficient (ICC) and Bland-Altman analysis in multivendor.Main results. The results show that the average Dice of 0.92, 0.92, 0.94 and HD95 of 2.50, 1.36, 1.37 for three sequences. The automatic and manual results of seven parameters were excellently correlated with the lowestr2 value of 0.824 and the highest of 0.983. The ICC (0.908-0.989,P< 0.001) showed that the results were highly consistent. Bland-Altman with a 95% limit of agreement showed there was no significant difference except for the difference in RVESV (P= 0.005) and LVM (P< 0.001).Significance. The model had high accuracy in segmentation and excellent correlation and consistency in function assessment. It provides a fast and effective method for studying cardiac MRI and heart disease.


Assuntos
Imagem Cinética por Ressonância Magnética , Redes Neurais de Computação , Imagem Cinética por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos
17.
Diagnostics (Basel) ; 13(20)2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37891983

RESUMO

This study investigates the crucial factors influencing the end-systolic and end-diastolic volumes in MRI volumetry and their direct effects on the derived functional parameters. Through the simultaneous acquisition of 2D-cine and 3D whole-heart slices in end-diastole and end-systole, we present a novel direct comparison of the volumetric measurements from both methods. A prospective study was conducted with 18 healthy participants. Both 2D-cine and 3D whole-heart sequences were obtained. Despite the differences in the creation of 3D volumes and trigger points, the impact on the LV volume was minimal (134.9 mL ± 16.9 mL vs. 136.6 mL ± 16.6 mL, p < 0.01 for end-diastole; 50.6 mL ± 11.0 mL vs. 51.6 mL ± 11.2 mL, p = 0.03 for end-systole). In our healthy patient cohort, a systematic underestimation of the end-systolic volume resulted in a significant overestimation of the SV (5.6 mL ± 2.6 mL, p < 0.01). The functional calculations from the 3D whole-heart method proved to be highly accurate and correlated well with function measurements from the phase-contrast sequences. Our study is the first to demonstrate the superiority of 3D whole-heart volumetry over 2D-cine volumetry and sheds light on the systematic error inherent in 2D-cine measurements.

18.
Med Image Anal ; 90: 102975, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37804586

RESUMO

Cine magnetic resonance imaging (MRI) is the current gold standard for the assessment of cardiac anatomy and function. However, it typically only acquires a set of two-dimensional (2D) slices of the underlying three-dimensional (3D) anatomy of the heart, thus limiting the understanding and analysis of both healthy and pathological cardiac morphology and physiology. In this paper, we propose a novel fully automatic surface reconstruction pipeline capable of reconstructing multi-class 3D cardiac anatomy meshes from raw cine MRI acquisitions. Its key component is a multi-class point cloud completion network (PCCN) capable of correcting both the sparsity and misalignment issues of the 3D reconstruction task in a unified model. We first evaluate the PCCN on a large synthetic dataset of biventricular anatomies and observe Chamfer distances between reconstructed and gold standard anatomies below or similar to the underlying image resolution for multiple levels of slice misalignment. Furthermore, we find a reduction in reconstruction error compared to a benchmark 3D U-Net by 32% and 24% in terms of Hausdorff distance and mean surface distance, respectively. We then apply the PCCN as part of our automated reconstruction pipeline to 1000 subjects from the UK Biobank study in a cross-domain transfer setting and demonstrate its ability to reconstruct accurate and topologically plausible biventricular heart meshes with clinical metrics comparable to the previous literature. Finally, we investigate the robustness of our proposed approach and observe its capacity to successfully handle multiple common outlier conditions.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Tórax , Imageamento Tridimensional/métodos
19.
BMC Cardiovasc Disord ; 23(1): 473, 2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37735355

RESUMO

PURPOSE: Highly accelerated compressed sensing cine has allowed for quantification of ventricular function in a single breath hold. However, compared to segmented breath hold techniques, there may be underestimation or overestimation of LV volumes. Furthermore, a heterogeneous sample of techniques have been used in volunteers and patients for pre-clinical and clinical use. This can complicate individual comparisons where small, but statistically significant differences exist in left ventricular morphological and/or functional parameters. This meta-analysis aims to provide a comparison of conventional cine versus compressed sensing based reconstruction techniques in patients and volunteers. METHODS: Two investigators performed systematic searches for eligible studies using PubMed/MEDLINE and Web of Science to identify studies published 1/1/2010-3/1/2021. Ultimately, 15 studies were included for comparison between compressed sensing cine and conventional imaging. RESULTS: Compared to conventional cine, there were small, statistically significant overestimation of LV mass, underestimation of stroke volume and LV end diastolic volume (mean difference 2.65 g [CL 0.57-4.73], 2.52 mL [CL 0.73-4.31], and 2.39 mL [CL 0.07-4.70], respectively). Attenuated differences persisted across studies using prospective gating (underestimated stroke volume) and non-prospective gating (underestimation of stroke volume, overestimation of mass). There were no significant differences in LV volumes or LV mass with high or low acceleration subgroups in reference to conventional cine except slight underestimation of ejection fraction among high acceleration studies. Reduction in breath hold acquisition time ranged from 33 to 64%, while reduction in total scan duration ranged from 43 to 97%. CONCLUSION: LV volume and mass assessment using compressed sensing CMR is accurate compared to conventional parallel imaging cine.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Ventrículos do Coração , Suspensão da Respiração , Espectroscopia de Ressonância Magnética
20.
J Clin Med ; 12(18)2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37762895

RESUMO

BACKGROUND: The pathophysiology of this association of type 1 Chiari malformation (CM1) and syrinxes is still unknown. There is an alteration in the dynamics of neurofluids (cerebrospinal fluid, arterial and venous blood) during the cardiac cycle in CM1. Our objective is to quantify CSF or arterial blood or venous blood flow in patients with Chiari syndrome (CS) with and without syrinxes using phase-contrast MRI (PCMRI). METHODS: We included 28 patients with CM1 (9 with syrinxes, 19 without). Morphological MRI with complementary PCMRI sequences was performed. We analyzed intraventricular CSF, subarachnoid spaces CSF, blood, and tonsillar pulsatility. RESULTS: There is a highly significant correlation (p < 0.001) between cerebral blood flow, cerebral vascular expansion volume and venous drainage distribution. Venous drainage distribution is significantly inversely correlated with oscillatory CSF volume at the level of the foramen magnum plane [-0.37 (0.04)] and not significantly correlated at the C2C3 level [-0.37 (0.05)] over our entire population. This correlation maintained the same trend in patients with syrinxes [-0.80 (<0.01)] and disappeared in patients without a syrinx [-0.05 (0.81)]. CONCLUSION: The distribution of venous drainage is an important factor in intracranial homeostasis. Impaired venous drainage would lead to greater involvement of the CSF in compensating for arterial blood influx, thus contributing to syrinx genesis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...